Smart Tissue Processor
During the day, LOGOS One EVO can run
urgent biopsies in a short time as a fully automated unit. Molten wax is
automatically transferred to and from the processing retort for the
impregnation step.
During the night, LOGOS One EVO can run
protocols as an advanced and resistant heated processor. Improved operations
are carried out through xylene-free protocols with only four reagents:
formalin, ethanol, isopropanol and wax. It also has an optional delayed start
mode, with a desired completion time set by the user, to allow additional
fixation time, if needed.
·
DRAMATIC REAGENT SAVINGS
LOGOS One EVO tissue processor uses only 100% alcohol, resulting in
significantly lower consumption of reagents overall. When LOGOS One EVO is used
in dual mode, wax can last over a month as all the clearing reagent
(Isopropanol) is boiled off in the impregnation step. It delivers substantial
savings over 10 years that can equate to the capital purchase of the unit.
·
WORKFLOW UNDER YOUR CONTROL
Overnight and ultra-rapid tissue processing during the day will grant you the
highest degree of flexibility and control over your workflow.
·
DUAL MODE WITH NO DOWNTIME
In the dual mode configuration no wax is pumped in and out of the retort, and
no post run cleaning cycle is required.
·
XYLENE-FREE
·
LOGOS ONE EVO PRODUCES EXCELLENT IHC
QUALITY
Efficient processing combined with reduced chemical exposure, preserves IHC
signal.
·
ELIMINATE UNDER-PROCESSED TISSUES
LOGOS One EVO efficiency allows for processing larger or fatty tissue within a
normal timeline, eliminating the need for reprocessing and eliminating
under-processed tissues.
·
NO CHANGE TO YOUR IHC PROTOCOLS, THUS
QUICK VALIDATION
LOGOS One EVO tissue processor will run
with your fixative of choice, thus all downstream test results (IHC, FISH, ISH,
etc.) remain the same. No change to your protocol is required.
·
FULL COMPLIANCE
LOGOS One EVO can
operate with resistance heating only, and processes breast tissue for assessing
HER-2 in full compliance with CAP/ASCO guidelines and FDA HER-2 approved
testing, in accordance with heating mode, temperatures, and reagent types.
·
TIME SAVING
Direct transfer of solutions from commercial containers (5l / 1 US gal supplier
bottles) into the processing retort. No need of filling tanks as required by
conventional tissue processors.
·
HIGH SAFETY STANDARDS
No pouring, no fumes.
·
ULTRA PROTECTION FOR USER SAFETY
Fully enclosed system
with a twin extraction system of fumes at the retort opening. The slide-out
reagent drawer is provided with an efficient ventilation/exhaust system.
·
ERROR-FREE REAGENTS REPLACEMENT
The LOGOS One EVO reagent replacement is error-free thanks to a barcoding check
system. When the container needs to be replaced, the operator can double-check
the correctness of the reagent used and its positioning in the drawer.